TopPodcast.com
Menu
  • Home
  • Top Charts
  • Top Networks
  • Top Apps
  • Top Independents
  • Top Podfluencers
  • Top Picks
    • Top Business Podcasts
    • Top True Crime Podcasts
    • Top Finance Podcasts
    • Top Comedy Podcasts
    • Top Music Podcasts
    • Top Womens Podcasts
    • Top Kids Podcasts
    • Top Sports Podcasts
    • Top News Podcasts
    • Top Tech Podcasts
    • Top Crypto Podcasts
    • Top Entrepreneurial Podcasts
    • Top Fantasy Sports Podcasts
    • Top Political Podcasts
    • Top Science Podcasts
    • Top Self Help Podcasts
    • Top Sports Betting Podcasts
    • Top Stocks Podcasts
  • Podcast News
  • About Us
  • Podcast Advertising
  • Contact
Not in our directory?
Add Show Here
Podcast Equipment
Center

toppodcastlogoOur TOPPODCAST Picks

  • Comedy
  • Crypto
  • Sports
  • News
  • Politics
  • True Crime
  • Business
  • Finance

Follow Us

toppodcastlogoStay Connected

    View Top 200 Chart
    Back to Rankings Page
    Business

    HVAC School – For Techs, By Techs

    Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.

    Advertise
    • Apple Podcasts
    • Google Play
    • Spotify

    Latest Episodes:
    Floating vs. Fixed Suction and Head - Short #163 May 16, 2023
    Show notes

    In this short podcast episode, Bryan talks about compression ratio and efficiency, particularly how floating or fixed suction and head pressure affect those things.

    Compression ratio (absolute head pressure divided by absolute suction pressure) closely correlates to efficiency in all sorts of compression-refrigeration HVAC/R systems; the most efficient systems have high mass flow with less compressor work. High compression ratios indicate a greater differential between the head and suction pressures. A lower compression ratio is desirable, but the number has to be realistic; a compression ratio of 1 indicates that the system is off. Medium-temp refrigeration compression ratios are typically around 3:1, whereas low-temp refrigeration can have higher compression ratios (6:1).

    In commercial refrigeration applications, we can help control the compression ratio with floating suction and head strategies. Floating the suction and head pressures allow the equipment to achieve lower compression ratios and higher equipment efficiency. Old strategies for controlling compression ratio would involve having a fixed evaporator temperature and suction pressure. In a parallel rack system, floating suction allows the suction pressure to float up when the case maintains temperature; this strategy helps close the gap between the absolute suction and absolute head pressures and reduces the compression ratio.

    Floating suction strategies allow the suction to "float" up by allowing the evaporator coil temperature to rise a little bit when the box temperature is under control. Floating head strategies, on the other hand, allow the head pressure to float down in low-ambient conditions. We can look at ambient temperature and discharge pressure to determine how much we can float down the head pressure.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Humidity Utopia w/ Nikki & Bryan May 11, 2023
    Show notes

    This podcast episode is Nikki Krueger (Santa Fe Dehumidifiers) and Bryan's 2023 HVACR Training Symposium session about how we can optimize dehumidification and efficiency to create an HVAC design and humidity utopia.

    While we attempt to achieve comfort and high indoor air quality in humid climates, we may find challenges integrating these with the HVAC system and getting customers to understand the need for proper dehumidification. Older homes that are built "leaky" allow for uncontrolled infiltration and exfiltration, but newer constructions are a lot tighter and rely on mechanical ventilation to control where the outdoor air comes from and make sure it is properly filtered and distributed.

    We deal with both sensible and latent BTUs in a home, and we can't treat them as though they're all equal. Many high-efficiency systems have high sensible heat ratios (SHRs) and are designed to remove sensible BTUs very efficiently, but they're not adequate at removing latent BTUs. Ideally, we would rely on an A/C system or heat pump to dehumidify the air in cooling mode before adding a dehumidifier. However, some of the systems that are best equipped to handle high latent loads will be less efficient.

    If you wish to install supplemental humidification, the ideal design will have a dedicated return and tie into the main HVAC supply duct.

    Nikki and Bryan also discuss:

    • Willis Carrier's real invention
    • Strategies for reducing conductive, convective, and radiant gains
    • Understanding relative humidity and dew point
    • Design loads
    • Electrification and energy efficiency incentives
    • Adiabatic heating and cooling
    • Single-stage vs. multi-stage equipment
    • Dehumidification for ductless mini-splits
    • Supplemental dehumidifier designs

    Learn more about Santa Fe Dehumidifiers at https://www.santa-fe-products.com/.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    What the Flux? - Short #162 May 09, 2023
    Show notes

    This is the episode for you if you've ever asked, "What the flux?" In this short podcast, Bryan explains the basics of flux in soldering and brazing, as well as magnetism.

    Flux means "flow." In HVAC, "flux" may have two meanings. It may refer to the substance that helps the molten alloy flow and bond to base metals more effectively when you're soldering or brazing. However, flux may also refer to magnetic flux, which is the lines of force that emanate from a magnet; this concept is important in inductive loads like transformers.

    In soldering, brazing, and welding, flux is a powder-paste or liquid that you apply to the base metal. You usually apply it directly to the male side of the base metal, or it may be embedded in the brazing alloy. Flux prevents oxides (like rust or the black flakes, cupric oxide) from forming on the surface you're brazing, which commonly happens at higher temperatures. Flux helps you create a proper bond, but it doesn't eliminate the need to clean the base metal before brazing.

    You typically don't need flux when you use silver-phosphorus or phosphorus-copper brazing rods for copper-to-copper brazing; the phosphorus acts as a fluxing agent, and using flux may increase the risk of contamination. It's also important to remove the flux from the metal after brazing because it may cause pitting; you may use a brush and/or a wet rag.

    Flux is useful when you use rods with high silver content or when you have other base metals; the appropriate flux will depend on the base metal, especially if you're soldering aluminum.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    The Impacts of Duct Leakage w/ Steve Rogers May 04, 2023
    Show notes

    Steve Rogers from The Energy Conservatory (TEC) returns to the podcast to discuss the impacts of duct leakage on occupant comfort and HVAC system performance.

    Duct leakage has more significant negative effects in heat pump systems than in furnace systems, especially in climates with high heating, cooling, or latent loads, due to pressure imbalances and moisture problems. You can measure duct leakage by masking off all supply and return registers, attaching a calibrated fan, and running the duct blaster to pressurize the duct work to 25 Pascals.

    Exhaust-only ventilation presents many of the same problems as duct leakage, particularly in the humid South. The duct leakage allowable by code (in Florida) is almost equivalent to a 50-CFM bathroom fan.

    Leakage often happens on the supply side, and it is important to determine whether the leakage is happening on the supply or return side; you may lose significant capacity on the supply side, and you may lose a little less capacity if the leakage is primarily on the return side. That capacity, however, is often heavily latent, leading to potential moisture problems (though less so in cold climates). Duct leakage may go outside or merely into an unconditioned space within the home; you can test the duct leakage outside with a duct blaster and a blower door simultaneously.

    Steve and Bryan also discuss:

    • Duct leakage problem differences in the North and South
    • Regulations and their effects on changeout practices
    • Using powered flow hoods and a TrueFlow grid to measure duct leakage
    • Duct leakage allowable by code
    • Home construction types and duct configuration
    • Envelope leakage
    • Leakage testing and pricing
    • Low-Income Heating Assistance Program (LIHEAP)

    Learn more about TEC at https://energyconservatory.com/.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Launch of the Sensi Touch 2 Thermostat May 02, 2023
    Show notes

    Tom Lorenz from Sensi joins the podcast to talk about the launch of the Sensi Touch 2 thermostat. The Sensi Touch 2 smart thermostat is compatible with room sensors, which makes it an efficient and effective thermostat.

    Smart thermostats are becoming more common in homes, especially as we focus on HVAC efficiency. Designers are aiming to make smart thermostats user-friendly, aesthetically pleasing, easy to install, and driven by data (via sensors).

    Installation is easy for contractors, as it relies on push terminals and cleanly covers up the previous thermostat's installation site. The Sensi Touch 2 requires a common wire, but it has easy-to-use push terminals that allow wires to click into place. It also has dedicated accessory terminals for add-on equipment like dehumidifiers. You can also pair the Sensi Touch 2 with its respective app to program the thermostat.

    Smart maintenance automatically alerts homeowners about poor performance or efficiency. These sorts of alerts can offer peace of mind for the homeowner. The room sensors allow the Sensi Touch 2 to manage home comfort by collecting data from several locations of the house; you can sync up to 15 room sensors to the Sensi Touch 2 thermostat.

    As with other Sensi thermostats, the Sensi Touch 2 has contractor branding capabilities. You can get your company name and number programmed into the main display so that the customers know who to call whenever they need something. You can learn more at procontractorbranding.com.

    Tom and Bryan also discuss:

    • History of Emerson, White-Rodgers, and Sensi controls
    • Personal data and privacy concerns with smart technology
    • Smart thermostat design and aesthetics
    • Energy Star certification
    • Sensi Lite (coming soon)
    • Warranty information

    Learn more about the Sensi Touch 2 at https://sensi.copeland.com/en-us/for-professionals/touch2-smart-thermostat.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Why and How to Create an Internal Training Program W/ Eugene S. Apr 27, 2023
    Show notes

    Eugene Silberstein from ESCO Group returns to the podcast to discuss why and how to create an internal training program for your HVAC/R company.

    HVAC/R has so many niches, and information and practices are always evolving, so lifelong learning is necessary for the industry. In-house training is a form of education that can come with many benefits, including control over scheduling, building community within the organization, and convenience. However, creating an in-house training program also comes with many challenges, including time and money expenses.

    For an internal training program to work, there needs to be a clear commitment to lifelong education that is ingrained in the culture. That could include bringing in other educators, setting up mentorship programs, and partnering with local trade schools. Unlike an external training program, an in-house training program also allows you to tailor education to your technicians' goals and needs.

    A good in-house training program creates an environment of psychological safety; it allows trainees to ask questions without feeling singled out or judged. Some people who know topics well aren't the best trainers; trainers need to know how to teach others, which means understanding how the human mind works.

    Commitment is ultimately what makes or breaks an internal training program. If your trainees can see that you are investing in them consistently, they will be more likely to give and get the most out of the training program.

    Eugene and Bryan also discuss:

    • The hunger and need for HVAC/R education
    • Benefits and drawbacks of external training
    • Using mistakes and callbacks as learning experiences
    • Educators who make trainees feel safe
    • Education, engagement, and entertainment
    • Will technicians leave your company if you train them?
    • Casual but deliberate training

    Learn more about ESCO Group's HVACR learning network at https://hvacr.elearn.network/.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    When Subcooling is Meaningless - Short #161 Apr 25, 2023
    Show notes

    In this short podcast, Bryan talks about the times when subcooling is meaningless. It is important to understand subcooling fully before using it as a charging or diagnostic method, particularly in refrigeration systems.

    When we need to charge TXV systems in residential HVAC, many technicians rely on subcooling to set the charge. However, refrigeration systems don't quite work the same way; charging a refrigeration system by subcooling may lead you to overcharge the system.

    We take subcooling on the liquid line between the condenser and the metering device. The condenser takes superheated vapor and rejects heat. This process turns the superheated vapor refrigerant into a liquid-vapor mixture midway through and subcools the liquid refrigerant at the bottom of the condenser. That liquid "stacks" at the bottom of the condenser. Adding more refrigerant will cause more liquid refrigerant to stack up at the end of the condenser and increase subcooling. These conditions can cause an increase in head pressure.

    However, many refrigeration systems have receivers between the metering device and the condenser. Excess refrigerant gets stored in the receiver; it doesn't stack up in the condenser, and it doesn't contribute to additional subcooling. As the liquid line fills and the metering device restricts, the liquid goes into the receiver, not the condenser. Subcooling won't change much until the receiver is full, which is a major problem; receivers should only be up to 80% full, even when pumped down. So, we rely on sight glasses or receiver-level monitors to determine the charge, not subcooling. The goal is to keep the sight glass clear, meaning there is a full line of liquid going to the metering device. (However, sight glasses will also be clear when the system is off or empty.)

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Solving Work Life Imbalance w/ Craig M Apr 20, 2023
    Show notes

    Craig M (AC Service Tech) returns to the podcast to talk about solving work-life imbalance, especially for HVAC/R technicians who have children and families of their own.

    Our actions tend to be driven by our priorities, which vary at different stages of our lives. Someone's work-life balance could also vary depending on different parts of the year. When we let the right people into our lives and are surrounded by supportive communities, we can reconfigure our personal and career trajectories to keep them in line with our priorities. To create a healthy work-life balance, we must be open to investing in others and letting others invest in us.

    "Balance" implies a constant state of evenness, but for people who work many hours, own a business, or have a family, their time may not be perfectly balanced at all times. That sort of variety presents a challenge, but it also presents opportunities for us to invite wise counsel and maintain communication to make sure we're on the same page as the important people in our lives.

    We are imperfect, and in many cases, we make mistakes when we do things we shouldn't do or fail to do things we should do. When we make those mistakes or bad things happen, we can think about practical measures we can immediately implement in our lives to make them more fulfilling in terms of our long-term vision.

    Craig and Bryan also discuss:

    • Providing for one's family
    • Seeking counsel and wisdom from others
    • How lifestyles and priorities shift as children grow up
    • Intentionality and short-term vs. long-term thinking
    • Making the "right" decision
    • Letting people struggle but supporting them
    • Emotional maturity
    • Authenticity
    • Bringing positivity to communication and relationships

    Learn more about Craig's books and other educational resources at https://www.acservicetech.com/.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    ROT Can Cause Duct Issues - Short #160 Apr 18, 2023
    Show notes

    In this short podcast, Bryan explains how rules of thumb (ROT) can cause duct issues. He talks about the role of friction rate in duct design as well as its intent and limitations.

    Friction rate is a value located on duct calculation tools, including Ductulators. We use friction rate to predict the operating static pressure of the system, but it is often misapplied when people design their ductwork around rules of thumb. The friction rate is expressed in inches of water column ("WC), which we also use to measure static pressure. However, the operational static pressure and friction rate are NOT the same things.

    Ductulators provide information about friction rate based on 100 feet of straight ductwork in the size selected, which we almost never see in the field; fittings and turns add effective length (EL), so the total effective length (TEL) is often more than 100 feet. When duct designers apply rules of thumb, like a 0.1" friction rate, and apply it to the CFM, they don't consider the actual length of the duct. So, the ducts are often undersized and don't properly account for the actual resistance to airflow.

    If you want to stop using rules of thumb, ACCA Manual D and related software can help you get more precise design parameters and account for other restrictions.

    The following tech tips contain more information and specific equations to help you find the total effective length: The Friction Rate Chart (and What it Means), What the Heck is a Friction Rate? (Eric Kaiser), How to Determine the Friction Rate for Residential Duct Design (Neil Comparetto).

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Heart of a Teacher w/ Craig M. Apr 13, 2023
    Show notes

    Craig Migliaccio (AC Service Tech) returns to the podcast to talk about what it means to have the heart of a teacher.

    Craig discovered his passion for teaching while instructing apprentices on the job, and he went into institutionalized teaching from there. He chose to overcome several administrative obstacles to become eligible as a teacher at technical schools, and that perseverance is one aspect of the "heart of a teacher."

    One of the most rewarding aspects of teaching is the investment in others. For Craig, HVAC is a tool for supporting someone's family, and a teacher can find a sense of purpose in helping people be better HVAC practitioners. When good teachers invest in their students or apprentices, they give those people a reason to take pride in their work.

    The job of a teacher isn't to give students the answer, which can be frustrating for students and the teachers of those frustrated students. People who have the heart of a teacher allow students to learn things themselves and be frustrated when they don't receive the answer immediately. Teachers ultimately care and want to keep improving, and they get their students to ask questions. The most important aspect of teaching is getting students to retain knowledge and build on it, and many students retain knowledge when they get to ask questions on their own and apply their knowledge.

    Craig and Bryan also discuss:

    • Craig's experience with teaching licensure
    • The intrinsic desire to share knowledge or skills
    • Investing in others during a labor shortage
    • Switching mindsets
    • Monologuing vs. asking questions
    • Continuous improvement as a teacher
    • Impostor syndrome and teaching
    • Making educational content more valuable
    • Limitations of video/audio education

    Learn more about Craig's books and other educational resources at https://www.acservicetech.com/.

    Learn more about the HVACR Training Symposium or buy a virtual ticket today at https://hvacrschool.com/symposium.

    If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.

    Check out our handy calculators HERE.


    Previous 1 33 34 35 36 37 95 Next

    Related Podcasts

    How I Built This with Guy Raz

    1

    How I Built This with Guy Raz Business
    Planet Money

    2

    Planet Money Business
    Inside Strategic Coach: Connecting Entrepreneurs With What Really Matters

    3

    Inside Strategic Coach: Connecting Entrepreneurs With What Really Matters Business
    BiggerPockets Real Estate Podcast

    4

    BiggerPockets Real Estate Podcast Business
    The Smart Passive Income Online Business and Blogging Podcast

    5

    The Smart Passive Income Online Business and Blogging Podcast Business
    Bad With Money With Gabe Dunn

    6

    Bad With Money With Gabe Dunn Business
    footer-logo

    Contact Us

    Toll Free: 844-670-7747

    Links

    • Home
    • Top Charts
    • Networks
    • Apps
    • Independents Podcasts
    • Podcast Advertising
    • Podcast News
    • Contact Us
    • About Us
    • Analytics & Insights

    Stay Connected

      Privacy, Terms of Use & Our Code of Ethics Protecting Content Creators Copyrights