TopPodcast.com
Menu
  • Home
  • Top Charts
  • Top Networks
  • Top Apps
  • Top Independents
  • Top Podfluencers
  • Top Picks
    • Top Business Podcasts
    • Top True Crime Podcasts
    • Top Finance Podcasts
    • Top Comedy Podcasts
    • Top Music Podcasts
    • Top Womens Podcasts
    • Top Kids Podcasts
    • Top Sports Podcasts
    • Top News Podcasts
    • Top Tech Podcasts
    • Top Crypto Podcasts
    • Top Entrepreneurial Podcasts
    • Top Fantasy Sports Podcasts
    • Top Political Podcasts
    • Top Science Podcasts
    • Top Self Help Podcasts
    • Top Sports Betting Podcasts
    • Top Stocks Podcasts
  • Podcast News
  • About Us
  • Podcast Advertising
  • Contact
Not in our directory?
Add Show Here
Podcast Equipment
Center

toppodcastlogoOur TOPPODCAST Picks

  • Comedy
  • Crypto
  • Sports
  • News
  • Politics
  • True Crime
  • Business
  • Finance

Follow Us

toppodcastlogoStay Connected

    View Top 200 Chart
    Back to Rankings Page
    Technology

    Advanced Refrigeration Podcast

    This podcast is for the education of supermarket and commercial refrigeration systems.
    We will be going over operation troubleshooting and diagnostic on multiple types of systems including mechanical and energy management

    Advertise

    Copyright: © Brett Wetzel & Kevin Compass

    • Apple Podcasts
    • Google Play
    • Spotify

    Latest Episodes:
    Dorin Compressor Software ,, What Can I Use It For ??? & Brett Gets A TOOF Episode 529 Audio Jul 20, 2026
    Show notes

    Dorin Compressor Software What Can I Use It For & Brett Gets A TOOF Episode 529

    Dorin CO₂ App Walkthrough + Heatwave Rack Chaos (Advanced Refrigeration Podcast)

    Brett Wetzel and Kevin Compass open with jokes about Brett’s new tooth causing a lisp before diving into brutal Chicagoland heat (95°F+ for two weeks) and how it’s hammering CO₂ racks, especially systems without adiabatics. Kevin describes racks struggling at peak hours, capacity gaps where a second compressor is too large, VFDs stuck at minimum, low suction, rising discharge temps, overload trips, and heavy flash gas with bypass valves 50–60% open, with gas cooler outlet temps around 97–98°F (near ambient). They discuss limited quick fixes, defrost scheduling problems, and controller wiring/programming hurdles. Brett then screen-shares a training-style walkthrough of the Dorin app for sizing and troubleshooting, entering typical inputs to estimate compressor selection, discharge temperature, amperage, and using those values diagnostically to spot issues like valve plate blow-by rather than relying on pump-down tests.


    Dorin Compressor Software,, What Can I Use It For ??? & Brett Gets A TOOF Episode 529 Video Jul 20, 2026
    Show notes

    Dorin Compressor Software What Can I Use It For & Brett Gets A TOOF Episode 529 Video

    Dorin CO₂ App Walkthrough + Heatwave Rack Chaos (Advanced Refrigeration Podcast)

    Brett Wetzel and Kevin Compass open with jokes about Brett’s new tooth causing a lisp before diving into brutal Chicagoland heat (95°F+ for two weeks) and how it’s hammering CO₂ racks, especially systems without adiabatics. Kevin describes racks struggling at peak hours, capacity gaps where a second compressor is too large, VFDs stuck at minimum, low suction, rising discharge temps, overload trips, and heavy flash gas with bypass valves 50–60% open, with gas cooler outlet temps around 97–98°F (near ambient). They discuss limited quick fixes, defrost scheduling problems, and controller wiring/programming hurdles. Brett then screen-shares a training-style walkthrough of the Dorin app for sizing and troubleshooting, entering typical inputs to estimate compressor selection, discharge temperature, amperage, and using those values diagnostically to spot issues like valve plate blow-by rather than relying on pump-down tests.


    Sporlan S3C, Comm Loops, Fireman's Dump Line, Brett's Retiring, and Noodling Episode 528 Audio Jul 13, 2026
    Show notes

    Sporlan S3C, Comm Loops, Fireman's Dump Line, Brett's Retiring, and Noodling Episode 528


    Fishing Fails, Target Startup Nightmares & Chicago Fireman’s Dump Lines | Advanced Refrigeration Podcast


    Brett Wetzel and Kevin Compass open with fishing stories and then jump into a rough Target CO2 startup plagued by miswired comm loops, mixed case-control hardware, and constant walking in a multi-level downtown layout. They discuss troubleshooting methods for crisscrossed MODbus wiring, common causes of shorts and opens, and an electrician mistake that blew an XM controller apart. The hosts explain Chicago’s “fireman’s dump line” code requirement and how piping it off the bottom of a suction header can trap oil and cause recurring low-oil issues. They also flag a backwards high-pressure control/relay setup on a Target backup CO2 unit, share practical tips for S3C/Corelink/CC200 case controllers, Ethernet jumpers, termination, protecting solid-state outputs, transducer orientation, and water-damaged controllers from case washing.


    Sporlan S3C, Comm Loops, Fireman's Dump Line, Brett's Retiring, and Noodling Episode 528 Video Jul 13, 2026
    Show notes

    Fishing Fails, Target Startup Nightmares & Chicago Fireman’s Dump Lines | Advanced Refrigeration Podcast


    Brett Wetzel and Kevin Compass open with fishing stories and then jump into a rough Target CO2 startup plagued by miswired comm loops, mixed case-control hardware, and constant walking in a multi-level downtown layout. They discuss troubleshooting methods for crisscrossed MODbus wiring, common causes of shorts and opens, and an electrician mistake that blew an XM controller apart. The hosts explain Chicago’s “fireman’s dump line” code requirement and how piping it off the bottom of a suction header can trap oil and cause recurring low-oil issues. They also flag a backwards high-pressure control/relay setup on a Target backup CO2 unit, share practical tips for S3C/Corelink/CC200 case controllers, Ethernet jumpers, termination, protecting solid-state outputs, transducer orientation, and water-damaged controllers from case washing.


    E3, Pack Controller, I Pro, O my Brett Looks Like He’s From Arkansas!! Episode 527 Video Jul 06, 2026
    Show notes

    E3, Pack Controller, I Pro, O my Brett Looks Like He’s From Arkansas!! Episode 527

    Post-Anesthesia Tech Tips: iPRO V5 ADF File Failures, Valve Driver Mix-Ups & Danfoss Tunneling Gotchas


    Brett and Kevin kick off the Advanced Refrigeration Podcast with Brett fresh out of oral surgery and sounding “absolutely hammered,” then pivot into startup tips for new CO₂ racks using E3/E2 controllers with iPROs. They warn that many OEM programs load the wrong ADF files—using iPRO CO2 instead of the iPRO V5 ADF—causing pressures/temps to read correctly while the HPV stays at 0% and won’t open, potentially high-heading and shutting the rack down; the fix involves deleting old ADF files and fully reprogramming the application. They also cover common configuration mistakes like valve steps being “x10,” assigning valves to the wrong drivers on V5 dual-driver setups, verifying peak/holding current and step rates for Danfoss valves, checking swapped T1/T2 sensors, and adding backup network P/T sensors for redundancy. Finally, they describe Danfoss PAC/System Manager tunneling being disabled after about eight hours for security, a Danfoss controller IP-address glitch that may require toggling HTTPS/DHCP or reloading the program, and the importance of correct HTTP vs HTTPS ports when connecting remotely.


    E3, Pack Controller, I Pro, O my Brett Looks Like He’s From Arkansas!! Episode 527 - Audio Jul 06, 2026
    Show notes

    E3, Pack Controller, I Pro, O my Brett Looks Like He’s From Arkansas!! Episode 527 Post-Anesthesia Tech Tips: iPRO V5 ADF File Failures, Valve Driver Mix-Ups & Danfoss Tunneling GotchasBrett and Kevin kick off the Advanced Refrigeration Podcast with Brett fresh out of oral surgery and sounding “absolutely hammered,” then pivot into startup tips for new CO₂ racks using E3/E2 controllers with iPROs. They warn that many OEM programs load the wrong ADF files—using iPRO CO2 instead of the iPRO V5 ADF—causing pressures/temps to read correctly while the HPV stays at 0% and won’t open, potentially high-heading and shutting the rack down; the fix involves deleting old ADF files and fully reprogramming the application. They also cover common configuration mistakes like valve steps being “x10,” assigning valves to the wrong drivers on V5 dual-driver setups, verifying peak/holding current and step rates for Danfoss valves, checking swapped T1/T2 sensors, and adding backup network P/T sensors for redundancy. Finally, they describe Danfoss PAC/System Manager tunneling being disabled after about eight hours for security, a Danfoss controller IP-address glitch that may require toggling HTTPS/DHCP or reloading the program, and the importance of correct HTTP vs HTTPS ports when connecting remotely.


    Electricians, CO2 Hot Gas Defrost, Danfoss EKE400 &  Parts Changing Process Of Elimination?- Episode-526 Audio Jun 29, 2026
    Show notes

    Target Startup Chaos, Buggy CoreLinks, andDanfoss EKE400/ICAD Headaches | Advanced Refrigeration Podcast

    Brett and Kevin open the AdvancedRefrigeration Podcast after a brutal week, with Brett stuck on a transcritical Kevinwith a startup at a poorly designed downtown store wherethe E3 and roof access are far from the grocery and the rack is on the roof. Heblames electricians for mis-marked and mixed-up comm lines, missingcontrol-power splices, and dangerous live voltages, turning a “simple” startupinto days of rework. They also vent about painfully slow, buggy CoreLinksetup and web UI issues compared to smoother E3 terminal mode. Kevin then walksthrough using a Danfoss EKE400 in CoolConfig for defrost and reheat control, MMRGdisplay jumper/address quirks, Modbus connection ideas, and generating wiringdiagrams. They finish with ICAD failures, O-ring moisture/rust problems, andsolving calibration alarms via process-of-elimination part swapping.


    Electricians, CO2 Hot Gas Defrost, Danfoss EKE400 &  Parts Changing Process Of Elimination?- Episode-526 video Jun 29, 2026
    Show notes

    Target Startup Chaos, Buggy CoreLinks, andDanfoss EKE400/ICAD Headaches | Advanced Refrigeration Podcast

    Brett and Kevin open the AdvancedRefrigeration Podcast after a brutal week, with Brett stuck on a transcritical Kevinwith a startup at a poorly designed downtown store wherethe E3 and roof access are far from the grocery and the rack is on the roof. Heblames electricians for mis-marked and mixed-up comm lines, missingcontrol-power splices, and dangerous live voltages, turning a “simple” startupinto days of rework. They also vent about painfully slow, buggy CoreLinksetup and web UI issues compared to smoother E3 terminal mode. Kevin then walksthrough using a Danfoss EKE400 in CoolConfig for defrost and reheat control, MMRGdisplay jumper/address quirks, Modbus connection ideas, and generating wiringdiagrams. They finish with ICAD failures, O-ring moisture/rust problems, andsolving calibration alarms via process-of-elimination part swapping.


    USA VS Canada Training, And A 3 Time Gold Medalist, For Refrigeration ??? - Episode-525 Audio Jun 22, 2026
    Show notes

    Skills Canada Gold, Rack Life inNewfoundland, and the Great Apprenticeship Debate |


    Advanced Refrigeration Podcast In this episode of the Advanced Refrigeration Podcast, hosts Brett Wetzel and Kevin Compass welcome Devon Owens from Newfoundland, a three-time Skills Canada gold medalist, to talk shop andtrade some laughs. Devon breaks down Skills Canada—provincials, nationals, and worlds—plus the intense 15-hour two-day refrigeration build he finished as theonly competitor, featuring a two-evaporator, two-temperature system with EPRs, solenoids, transducers, a superheat controller, and an EEV. The conversationshifts to how Canadian apprenticeship schooling differs from U.S. union training, including unpaid full-time pre- eployment, block exams, pay-scale progression, and a challenging 125-question journeyman exam that spans everything from CO2 and ammonia to natural gas. They also touch on rack work,CO2 sites in Newfoundland, 600V power, and why water leaks can ruin your day.


    USA VS Canada Training, And A 3 Time Gold Medalist, For Refrigeration ??? - Episode-525 Video Jun 22, 2026
    Show notes

    Skills Canada Gold, Rack Life in Newfoundland, and the Great Apprenticeship Debate


    Advanced Refrigeration Podcast In this episode of the Advanced Refrigeration Podcast, hosts Brett Wetzel and Kevin Compass welcome Devon Owens from Newfoundland, a three-time Skills Canada gold medalist, to talk shop and trade some laughs. Devon breaks down Skills Canada—provincials, nationals, and worlds—plus the intense 15-hour two-day refrigeration build he finished as the only competitor, featuring a two-evaporator, two-temperature system with EPRs, solenoids, transducers, a superheat controller, and an EEV. The conversation shifts to how Canadian apprenticeship schooling differs from U.S. union training, including unpaid full-time pre-employment, block exams, pay-scale progression, and a challenging 125-question journeyman exam that spans everything from CO2 and ammonia to natural gas. They also touch on rack work, CO2 sites in Newfoundland, 600V power, and why water leaks can ruin your day.


    Previous 1 2 3 4 5 6 45 Next

    Related Podcasts

    Reply All

    1

    Reply All Games & Hobbies
    Inside VR & AR

    2

    Inside VR & AR Gadgets
    Note to Self

    3

    Note to Self News
    BrainStuff

    4

    BrainStuff Natural Sciences
    This Week in Tech (Audio)

    5

    This Week in Tech (Audio) News
    Hands-On Tech (Audio)

    6

    Hands-On Tech (Audio) Technology
    footer-logo

    Contact Us

    Toll Free: 844-670-7747

    Links

    • Home
    • Top Charts
    • Networks
    • Apps
    • Independents Podcasts
    • Podcast Advertising
    • Podcast News
    • Contact Us
    • About Us
    • Analytics & Insights

    Stay Connected

      Privacy, Terms of Use & Our Code of Ethics Protecting Content Creators Copyrights